End Uses and Energy Efficiency Measures and Rebates
The program measure list addresses the following major end uses:
- Comprehensive Lighting
- HVAC
- Refrigeration
- Food Service
- Controls
- Hot Water / Natural Gas
- Retrocommissioning (RCx) & related Non-Residential Retrofit (NRR) Measures
Peak Demand | Measure | Rebate | Cap (% total job) |
Any | All Lighting | 12¢/kWh | 100% |
Less than 500 kW | All Non-lighting | Varies; avg ~35¢/kWh | Varies; up to 100% |
500 kW or more | Non-Lighting NRR | 9-15¢/kWh + $100/kW | 50% |
Any | RCx | 9¢/kWh + $100/kW | 50% |
List of Measures
Lighting
All lighting technologies are eligible, including but not limited to various combinations of these sub-measures for both external and internal applications:
- 3rd Generation T8 Lamp and Electronic Ballast Systems
- Induction Lamps and Fixtures
- High-Intensity Discharge (HID) Lamps and Fixtures
- LED Lamps and Fixtures
- Compact Fluorescent Lamps (CFLs) and Fixtures
- Halogen Infrared (HIR) Lamps
- Occupancy Sensors and Controls
HVAC
- Package A/C tune-up (RCA)
- Package A/C coil clean
- Small commercial duct seal
- Efficient package terminal AC & HP
- Efficient packaged A/C (common areas)
Refrigeration
- Refrigeration door strip curtains
- Refrigerator door closers
- Refrigeration door heater controls
- Refrigeration drop-in ECM fan motors
- Comprehensive refrigeration measures
Food Service
- Kitchen fryers
- Large vat fryers
- Kitchen steamers
- Kitchen griddles
- Hot food holding cabinets
- Efficient ice machines
Controls
- Vending machine controls
- Plug load sensors/controls
- Kitchen vent demand controls
- Guest room EMS (PTAC controls)
Hot Water / Natural Gas
- Low Flow Showerheads
- Faucet aerators
- Ozone laundry system
- HW pipe insulation (low temp)
- HW tank insulation (low & high temp)
- Boiler replacements
- Generator-Absorber-Heat Exchanger
- High efficiency water heater
- High efficiency gas furnace
- Boiler tune-up
Retrocommissioning (RCx) & Related
What is Rectorcommissionsing (RCx)?
- Suite of EMS measures
- Ventilation rate normalization
- Chilled & hot water loop temp controls
- AC to WC condenser swap
- Make-up air IE cooling
- Economizer Tune-Up
- Pool Pumps (dual & variable speed)
- VFD motors for VAV fans
- VSD for chilled & hot water loop
- Efficient reciprocating Chillers
- 3-way to 2-way valve swap in CW loop
- Retrocommissioning (RCx)
- NRR measures (formerly RC103) related to Retrocommissioning
To sign up for your free, no obligation, energy survey or for more information please contact CasinoGreen at: 831-426-5925 x106.
Other measures may be added during the course of Program implementation. For a complete measure list please contact the Program Manager at: 831-426-5925 x106.